kWh to BTU converter (kilowatt-hours to British thermal units)
1 kilowatt-hour (kWh) equals about 3,412.14 BTU. To convert kWh to BTU, multiply by 3,412.14: BTU = kWh × 3,412.14.
So 10 kWh is 34,121.4 BTU and 1,000 kWh (1 MWh) is 3,412,142 BTU, about 3.41 MMBtu. Going back, 1 BTU is 0.000293071 kWh.
Kilowatt-hours to British thermal units formula
Formula
BTU = kWh × 3,412.14163313
Multiply a value in kilowatt-hours by 3,412.14163313 to get British thermal units. To go the other way, divide by 3,412.14163313.
Worked examples
Convert 1 kWh to BTU
3,600,000 J ÷ 1,055.05585262 J/BTU = 3,412.14 BTU
Both units are defined exactly in joules, so this division is the whole conversion. Its decimal never ends (3,412.1416331279…), so it is rounded to 3,412.14 here and to 12 digits in the converter.
Convert 25 kWh to BTU
25 kWh × 3,412.14 = 85,303.5 BTU
Dividing by the reverse factor gives the same answer: 25 ÷ 0.000293071 = 85,303.5 BTU.
Convert 1,000 kWh (1 MWh) to BTU
1,000 kWh × 3,412.14 = 3,412,142 BTU = 3.412 MMBtu
MMBtu means one million BTU. Writing electricity in MMBtu puts it on the same scale as natural gas, which is priced per MMBtu.
Heat from a 1,500 W space heater running 4 hours
1.5 kW × 4 h = 6 kWh, and 6 × 3,412.14 = 20,472.8 BTU
An electric resistance heater turns all the electricity it uses into heat in the room, so each kWh gives 3,412 BTU.
Heat from a heat pump with a COP of 3 using 2 kWh
2 kWh × 3 = 6 kWh of heat, and 6 × 3,412.14 = 20,472.8 BTU
A heat pump moves heat rather than making it, so it delivers its coefficient of performance (COP) times the electricity used. The same 2 kWh in a resistance heater gives only 6,824 BTU.
Convert a 3.5 kW air conditioner rating to BTU/h
3.5 kW × 3,412.14 = 11,942.5 BTU/h, about 1 ton of cooling
A kW rating is power, so the answer is BTU per hour, not BTU. The factor is the same 3,412.14 because 1 kW sustained for one hour is 1 kWh. The watts to BTU per hour converter handles power directly.
Compare 1 therm of gas with electricity
100,000 BTU ÷ 3,412.14 BTU/kWh = 29.307 kWh
A therm is 100,000 BTU, so 1 therm of gas holds the same heat as about 29.3 kWh. Multiply your electricity price per kWh by 29.3 to compare it with a gas price per therm, before any appliance losses.
Kilowatt-hours to British thermal units conversion table
| Kilowatt-hours (kWh) | British thermal units (BTU) | Megajoules (MJ) |
|---|---|---|
| 0.001 | 3.4121416 | 0.0036 |
| 0.01 | 34.121416 | 0.036 |
| 0.1 | 341.21416 | 0.36 |
| 0.25 | 853.03541 | 0.9 |
| 0.5 | 1,706.0708 | 1.8 |
| 1 | 3,412.1416 | 3.6 |
| 1.5 | 5,118.2124 | 5.4 |
| 2 | 6,824.2833 | 7.2 |
| 2.5 | 8,530.3541 | 9 |
| 3 | 10,236.425 | 10.8 |
| 3.5 | 11,942.496 | 12.6 |
| 4 | 13,648.567 | 14.4 |
| 5 | 17,060.708 | 18 |
| 6 | 20,472.85 | 21.6 |
| 7 | 23,884.991 | 25.2 |
| 7.5 | 25,591.062 | 27 |
| 8 | 27,297.133 | 28.8 |
| 9 | 30,709.275 | 32.4 |
| 10 | 34,121.416 | 36 |
| 12 | 40,945.7 | 43.2 |
| 15 | 51,182.124 | 54 |
| 20 | 68,242.833 | 72 |
| 25 | 85,303.541 | 90 |
| 30 | 102,364.25 | 108 |
| 50 | 170,607.08 | 180 |
| 100 | 341,214.16 | 360 |
| 250 | 853,035.41 | 900 |
| 500 | 1,706,070.8 | 1,800 |
| 1,000 | 3,412,141.6 | 3,600 |
| 10,000 | 34,121,416 | 36,000 |
Common kWh amounts in BTU
| Amount | Kilowatt-hours (kWh) | British thermal units (BTU) |
|---|---|---|
| 1 watt-hour (0.001 kWh) | 0.001 | 3.41214 |
| 100 W light bulb, 10 hours (1 kWh) | 1 | 3,412.14 |
| 1.5 kW (1,500 W) space heater, 1 hour | 1.5 | 5,118.21 |
| 3.5 kW heat pump or AC, 1 hour | 3.5 | 11,942.5 |
| 5 kW heat pump, 1 hour | 5 | 17,060.7 |
| 5.2 kW heat pump, 1 hour | 5.2 | 17,743.1 |
| 7.1 kW heat pump, 1 hour | 7.1 | 24,226.2 |
| 8 kW heater, 1 hour | 8 | 27,297.1 |
| 10 kW furnace element, 1 hour | 10 | 34,121.4 |
| 1 therm of natural gas (100,000 BTU) | 29.3071 | 100,000 |
| 900 kWh monthly electricity use | 900 | 3,070,930 |
| 1 MMBtu (1,000,000 BTU) | 293.071 | 1,000,000 |
| 1 MWh (1,000 kWh) | 1,000 | 3,412,140 |
What are kilowatt-hours and British thermal units?
Kilowatt-hour (kWh)
A kilowatt-hour is the energy of 1,000 watts sustained for one hour, exactly 3.6 megajoules. It is the unit on household electricity bills.
British thermal unit (IT, BTU)
The International Table British thermal unit is exactly 1,055.05585262 joules, roughly the heat needed to warm one pound of water by 1 °F. It rates furnaces, air conditioners and fuels.
Both units have exact definitions in joules. The kilowatt-hour is 3,600,000 J and the International Table BTU (BTU_IT) is 1,055.05585262 J, so 1 kWh = 3,600,000 ÷ 1,055.05585262 BTU. That fraction is exact, but its decimal never ends (3,412.1416331279…), so it is rounded for display and the converter carries 12 significant digits. Some sources print 3,413 (rounded up) or 3,414, which comes from the older thermochemical BTU of 1,054.35 J (3,600,000 ÷ 1,054.35 = 3,414.43). The US Energy Information Administration uses 3,412 BTU per kWh.
kWh vs kW, and BTU vs BTU/h. A kWh is an amount of energy, like a BTU. A kW is power, energy per unit time, like a BTU per hour. Heaters, heat pumps and air conditioners are rated in kW or BTU/h, and the same 3,412.14 converts between those two: 1 kW = 3,412.14 BTU/h, so a 5 kW heat pump is 17,060.7 BTU/h and a 10 kW unit is 34,121.4 BTU/h. To get energy, multiply the rating by the hours it runs. For power ratings, use the watts to BTU per hour converter or the tons of refrigeration to kilowatts converter.
1 kWh of electricity is not always 3,412 BTU of heat. The conversion is exact for energy, but what you get depends on the device. A resistance heater gives 3,412 BTU per kWh, a heat pump with a COP of 3 delivers about 10,236 BTU of heat per kWh it uses, and a power plant burns more than 3,412 BTU of fuel for each kWh it sends out, a ratio called its heat rate. The BTU to kWh converter goes the other way, and the energy converter covers joules, therms, calories and every other energy unit.
Power is energy per unit of time: a 2 kW heater uses 2 kWh in an hour. For watts, horsepower and BTU per hour, use the power converter. For the change between two bills, use the percent change calculator.
Practice problems
A heater uses 12 kWh in a day. How many BTU of heat is that?
12 × 3,412.14 = 40,945.7 BTU.
A heat pump is rated at 5 kW of heating. What is that in BTU/h?
5 × 3,412.14 = 17,060.7 BTU/h.
Which is more energy: 30 kWh or 1 therm (100,000 BTU)?
30 kWh × 3,412.14 = 102,364 BTU, so 30 kWh is slightly more. In kWh, 1 therm is 29.307 kWh.
Frequently asked questions
How many BTU are in 1 kWh?
1 kWh is about 3,412.14 BTU. One kWh is 3,600,000 J and one BTU is 1,055.05585262 J, so 3,600,000 ÷ 1,055.05585262 = 3,412.1416 BTU. Many references round it to 3,412.
How do you convert kWh to BTU?
Multiply the number of kWh by 3,412.14, or divide it by 0.000293071. For example, 50 kWh × 3,412.14 = 170,607 BTU.
What is the formula for kWh to BTU?
BTU = kWh × 3,412.14. The reverse formula is kWh = BTU × 0.000293071, which is the same as dividing BTU by 3,412.14.
How do I convert kW to BTU?
A kW is power, so it converts to BTU per hour: BTU/h = kW × 3,412.14. A 3.5 kW unit is 11,942.5 BTU/h. To get BTU of energy, multiply kW by the hours of running first to get kWh, then multiply by 3,412.14.
How do I convert 8 kW to BTU/hr?
8 kW × 3,412.14 = 27,297.1 BTU/h. If it runs for one hour, it delivers 8 kWh, or 27,297 BTU of energy.
How many kilowatts equal 1 BTU?
A BTU is energy, so it matches kilowatt-hours, not kilowatts: 1 BTU = 0.000293071 kWh. For power, 1 BTU/h = 0.000293071 kW, or 0.293071 W.
What is 1.5, 3.5, 5, 7.1 and 10 kW in BTU/h?
1.5 kW is 5,118.2 BTU/h, 3.5 kW is 11,942.5 BTU/h, 5 kW is 17,060.7 BTU/h, 7.1 kW is 24,226.2 BTU/h and 10 kW is 34,121.4 BTU/h. Multiply any kW value by 3,412.14.
How many BTU is 1,000 kWh?
1,000 kWh is 3,412,142 BTU, or about 3.41 MMBtu (million BTU).
Why do some charts say 1 kWh = 3,413 or 3,414 BTU?
3,413 is 3,412.14 rounded up. 3,414 comes from the thermochemical BTU (1,054.35 J) instead of the International Table BTU (1,055.05585262 J) used here. The difference is under 0.1%.
How many therms is 1 kWh?
1 kWh is about 0.0341214 therms, since a therm is 100,000 BTU. Going the other way, 1 therm is about 29.307 kWh.
Does 1 kWh of electricity give 3,412 BTU of heat?
In a resistance heater, yes, because all the electricity becomes heat. A heat pump gives more, its COP times 3,412 BTU per kWh, and a fuel-burning plant needs more than 3,412 BTU of fuel to make each kWh.
Sources and further reading
- NIST Guide to the SI (Special Publication 811), Appendix B: Conversion Factors (opens in a new tab), National Institute of Standards and Technology
- The International System of Units (SI Brochure), 9th edition (opens in a new tab), Bureau International des Poids et Mesures
- CODATA Recommended Values of the Fundamental Physical Constants: 2022 (opens in a new tab), National Institute of Standards and Technology
- Units and calculators explained: energy conversion calculators and heat content of fuels (opens in a new tab), U.S. Energy Information Administration
- What is the efficiency of different types of power plants? (heat rate) (opens in a new tab), U.S. Energy Information Administration
- Heat pump systems (opens in a new tab), U.S. Department of Energy