Cubic feet per minute to cubic meters per hour (CFM to m³/h)
1 cubic foot per minute (CFM) equals exactly 1.69901079552 cubic meters per hour (m³/h), about 1.699.
To convert CFM to m³/h, multiply by 1.69901079552: m³/h = CFM × 1.69901079552. So 100 CFM is 169.9 m³/h, a 400 CFM range hood moves 679.6 m³/h and 1,000 CFM is 1,699 m³/h.
Cubic feet per minute to cubic meters per hour formula
Formula
m³/h = cfm × 1.69901079552
Multiply a value in cubic feet per minute by 1.69901079552 to get cubic meters per hour. To go the other way, divide by 1.69901079552. The factor is exact, because both units are defined exactly.
Worked examples
Convert 1 CFM to m³/h step by step
1 ft³ = 0.3048³ m³ = 0.028316846592 m³; 0.028316846592 m³/min × 60 min/h = 1.69901079552 m³/h
The foot is defined as exactly 0.3048 m, so a cubic foot is exactly 0.028316846592 m³. Converting minutes to hours multiplies by 60.
Convert a 100 CFM bathroom fan to m³/h
100 CFM × 1.69901079552 = 169.901 m³/h ≈ 169.9 m³/h
European fan datasheets list the same fan as about 170 m³/h.
Convert a 400 CFM range hood to m³/h
400 CFM × 1.69901079552 = 679.604 m³/h ≈ 679.6 m³/h
Range hoods sold in the US are rated in CFM; those sold in Europe and Asia are rated in m³/h.
Convert a 3-ton air conditioner (1,200 CFM) to m³/h
1,200 CFM × 1.69901079552 = 2,038.81 m³/h
Duct design often starts from about 400 CFM per ton of cooling, so a 3-ton system moves about 1,200 CFM.
Convert 5,000 CFM and 10,000 CFM to m³/h
5,000 CFM × 1.69901079552 = 8,495.05 m³/h; 10,000 CFM × 1.69901079552 = 16,990.11 m³/h
Large air handlers and industrial exhaust fans are rated in the thousands of CFM.
Estimate CFM to m³/h in your head
250 CFM × 1.7 = 425 m³/h (more precisely: 424.75 m³/h)
Multiplying by 1.7 gives an answer only 0.06% too high, which is close enough for sizing a fan.
Find air changes per hour from a fan rating
150 CFM × 1.69901079552 = 254.85 m³/h; room 5 m × 4 m × 2.5 m = 50 m³; 254.85 ÷ 50 = 5.1 air changes per hour
Air changes per hour (ACH) is the hourly airflow divided by the room volume, so it is easiest to work out in m³/h.
Convert 1,000 m³/h back to CFM
1,000 m³/h ÷ 1.69901079552 = 588.58 CFM
To go from m³/h to CFM, divide by 1.69901079552 or multiply by 0.588578, or use the cubic meters per hour to cubic feet per minute converter.
Cubic feet per minute to cubic meters per hour conversion table
| Cubic feet per minute (cfm) | Cubic meters per hour (m³/h) | Liters per second (L/s) | Cubic meters per minute (m³/min) |
|---|---|---|---|
| 1 | 1.69901 | 0.471947 | 0.0283168 |
| 2 | 3.39802 | 0.943895 | 0.0566337 |
| 5 | 8.49505 | 2.35974 | 0.141584 |
| 10 | 16.9901 | 4.71947 | 0.283168 |
| 20 | 33.9802 | 9.43895 | 0.566337 |
| 25 | 42.4753 | 11.7987 | 0.707921 |
| 50 | 84.9505 | 23.5974 | 1.41584 |
| 75 | 127.426 | 35.3961 | 2.12376 |
| 100 | 169.901 | 47.1947 | 2.83168 |
| 150 | 254.852 | 70.7921 | 4.24753 |
| 200 | 339.802 | 94.3895 | 5.66337 |
| 250 | 424.753 | 117.987 | 7.07921 |
| 300 | 509.703 | 141.584 | 8.49505 |
| 400 | 679.604 | 188.779 | 11.3267 |
| 500 | 849.505 | 235.974 | 14.1584 |
| 600 | 1,019.41 | 283.168 | 16.9901 |
| 750 | 1,274.26 | 353.961 | 21.2376 |
| 800 | 1,359.21 | 377.558 | 22.6535 |
| 1,000 | 1,699.01 | 471.947 | 28.3168 |
| 1,200 | 2,038.81 | 566.337 | 33.9802 |
| 1,500 | 2,548.52 | 707.921 | 42.4753 |
| 2,000 | 3,398.02 | 943.895 | 56.6337 |
| 2,500 | 4,247.53 | 1,179.87 | 70.7921 |
| 3,000 | 5,097.03 | 1,415.84 | 84.9505 |
| 4,000 | 6,796.04 | 1,887.79 | 113.267 |
| 5,000 | 8,495.05 | 2,359.74 | 141.584 |
| 6,000 | 10,194.1 | 2,831.68 | 169.901 |
| 7,500 | 12,742.6 | 3,539.61 | 212.376 |
| 8,000 | 13,592.1 | 3,775.58 | 226.535 |
| 10,000 | 16,990.1 | 4,719.47 | 283.168 |
| 12,000 | 20,388.1 | 5,663.37 | 339.802 |
| 13,000 | 22,087.1 | 6,135.32 | 368.119 |
| 15,000 | 25,485.2 | 7,079.21 | 424.753 |
| 20,000 | 33,980.2 | 9,438.95 | 566.337 |
Typical airflow ratings in CFM and m³/h
| Equipment | Cubic feet per minute (cfm) | Cubic meters per hour (m³/h) |
|---|---|---|
| Bathroom exhaust fan, ASHRAE 62.2 minimum | 50 | 84.951 |
| Bathroom exhaust fan, common rating | 80 | 135.92 |
| Kitchen range hood, ASHRAE 62.2 minimum | 100 | 169.9 |
| Kitchen range hood, typical | 400 | 679.6 |
| Air conditioner, 1.5 tons | 600 | 1,019.4 |
| Kitchen range hood, high output | 900 | 1,529.1 |
| Air conditioner, 3 tons | 1,200 | 2,038.8 |
| Air conditioner, 5 tons | 2,000 | 3,398 |
| Commercial air handler | 10,000 | 16,990 |
What are cubic feet per minute and cubic meters per hour?
Cubic foot per minute (cfm)
One cubic foot per minute is exactly 1.69901079552 m³/h. Fans, air compressors, range hoods and HVAC airflow are rated in CFM.
Cubic meter per hour (m³/h)
One cubic meter per hour is 1,000 liters per hour, a common rating for pumps, fans and ventilation systems.
The factor comes from exact definitions. Since 1959 the international foot has been exactly 0.3048 m, so a cubic foot is 0.3048³ = 0.028316846592 m³. An hour has 60 minutes, so 1 CFM = 0.028316846592 × 60 = 1.69901079552 m³/h with no rounding. Going the other way, 1 m³/h = 0.588578 CFM. The same units are written several ways: cfm, CFM, ft³/min and ft3/min for cubic feet per minute, and m³/h, m3/h, m3/hr and CMH for cubic meters per hour.
The most common mistake is forgetting the time step. Multiplying CFM by 0.0283168 alone gives cubic meters per minute, not per hour, a result 60 times too small. Another is mixing m³/h with m³/min: 1 CFM is 1.699 m³/h but only 0.0283 m³/min. Compressed air and gas specs add a third trap. SCFM and Nm³/h are volumes corrected to a reference temperature and pressure, so SCFM to Nm³/h is not 1.699. At the same pressure, 1 SCFM at 60 °F is about 1.607 Nm³/h, and 1 SCFM at 68 °F is about 1.583 Nm³/h, because normal cubic meters are measured at 0 °C.
CFM is the airflow unit for fans, air conditioners, range hoods, air purifiers and air compressors in the United States. Most other countries rate the same equipment in m³/h, or in L/s for ventilation codes and m³/min for compressors. One CFM is 0.471947 L/s and 0.0283168 m³/min, and the chart below shows all three. For the other direction use m³/h to CFM, and for gpm, L/min, cfs and the other units use the flow rate converter.
To work out how long a tank takes to fill, find its volume with the volume calculator and divide by the flow rate. For the tank size in other units, use the volume converter.
Practice problems
A range hood is rated at 300 CFM. What is that in m³/h?
300 × 1.69901079552 = 509.70 m³/h, about 510 m³/h.
A fan moves 80 CFM into a 30 m³ bathroom. How many air changes per hour is that?
80 × 1.69901079552 = 135.92 m³/h, and 135.92 ÷ 30 = 4.5 air changes per hour.
A European fan is rated at 850 m³/h. What is that in CFM?
850 ÷ 1.69901079552 = 500.29 CFM, about 500 CFM.
Frequently asked questions
How many m³/h is 1 CFM?
One cubic foot per minute is exactly 1.69901079552 m³/h, about 1.699 m³/h. A cubic foot is exactly 0.028316846592 m³, and an hour is 60 minutes, so 0.028316846592 × 60 = 1.69901079552.
How do I convert CFM to m³/h?
Multiply the CFM value by 1.69901079552. For example, 10 CFM × 1.69901079552 = 16.99 m³/h and 400 CFM × 1.69901079552 = 679.6 m³/h. For a quick estimate, multiply by 1.7.
How do I convert m³/h to CFM?
Divide by 1.69901079552, or multiply by 0.588578. For example, 1,000 m³/h ÷ 1.69901079552 = 588.58 CFM and 500 m³/h = 294.29 CFM.
How many m³/h is 1,000 CFM?
1,000 CFM is 1,699.01 m³/h. By the same factor, 4,000 CFM is 6,796.04 m³/h, 5,000 CFM is 8,495.05 m³/h and 10,000 CFM is 16,990.11 m³/h.
How do you convert cubic feet (CFT) to cubic meters?
Multiply by 0.028316846592. So 100 ft³ is 2.8317 m³, and 1 m³ is 35.3147 ft³. That converts a volume. To convert a flow such as CFM to m³/h, also multiply by 60 for the minutes in an hour. For volumes alone, use cubic feet to cubic meters or cubic meters to cubic feet.
How do I convert L/s to m³/h?
Multiply by 3.6, because 1 L/s is 0.001 m³ × 3,600 s = 3.6 m³/h. So 50 L/s is 180 m³/h. In CFM terms, 1 CFM is 0.471947 L/s and 1 L/s is 2.11888 CFM.
How do I convert feet per minute (FPM) to CFM?
Multiply the air speed in feet per minute by the duct area in square feet: CFM = FPM × ft². A 12 × 12 inch duct is 1 ft², so air at 600 FPM in it moves 600 CFM, which is 1,019.4 m³/h. FPM is a speed and CFM is a flow, so there is no single factor between them.
Can I convert SCFM to Nm³/h with the same factor?
No. SCFM and Nm³/h are measured at different reference temperatures, so the conversion needs a temperature correction. At the same pressure, 1 SCFM at 60 °F is about 1.607 Nm³/h, and 1 SCFM at 68 °F is about 1.583 Nm³/h. Use 1.699 only when both values are at the same conditions, such as actual CFM to actual m³/h.
Sources and further reading
- NIST Guide to the SI (Special Publication 811), Appendix B: Conversion Factors (opens in a new tab), National Institute of Standards and Technology
- NIST Handbook 44, Appendix C: General Tables of Units of Measurement (opens in a new tab), National Institute of Standards and Technology
- ANSI/ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Residential Buildings (opens in a new tab), ASHRAE