1 lux (lx) equals exactly 0.09290304 foot-candles (fc). To convert lux to foot-candles, multiply by 0.09290304: fc = lx × 0.09290304.

lx

1 lux equals

0.09290304foot-candles

fc = lx × 0.09290304

Exact conversion factor1 lx = 0.09290304 fc1 fc = 10.7639104167 lx
By Hira Noor, mathematicianLast reviewed Report a problem

Lux to foot-candles formula

Formula

fc = lx × 0.09290304

Multiply a value in lux by 0.09290304 to get foot-candles. To go the other way, divide by 0.09290304. The factor is exact, because both units are defined exactly.

Worked examples

  1. 500 lx office to foot-candles

    500 lx × 0.09290304 = 46.45152 fc

    A well-lit office designed to 500 lux reads about 46.5 fc on a US light meter.

  2. 1,000 lx overcast daylight to foot-candles

    1,000 lx × 0.09290304 = 92.90304 fc

    Outdoor light on an overcast day is on the order of 1,000 lux, about 93 fc.

  3. Lumens and area: 1,000 lm over 4 m² to foot-candles

    1,000 lm ÷ 4 m² = 250 lx; 250 lx × 0.09290304 = 23.23 fc

    Illuminance is lumens per area, so divide the lamp’s lumens by the lit area in square meters to get lux first, then convert to foot-candles.

OSHA minimum illuminance for construction work areas

Minimum illuminance OSHA requires for construction work areas, in lux and foot-candles (29 CFR 1926.56, Table D-3). These are legal minimums for construction sites, not general office design targets.
Work areaLux (lx)Foot-candles (fc)
General construction areas: excavation, waste areas, access ways, storage, loading platforms32.2923
Indoor warehouses, corridors, hallways and exitways53.825
Construction plant and shops: carpenter shops, batch plants, mechanical and electrical equipment rooms107.6410
First aid stations, offices and infirmaries322.9230

What are lux and foot-candles?

Lux (lx)

The lux is the SI unit of illuminance, one lumen spread evenly over one square meter. Light meters and lighting standards outside the United States use lux.

Foot-candle (fc)

A foot-candle is one lumen per square foot, about 10.764 lux. It is the usual illuminance unit in US building codes and lighting design.

The lux (lx) is the SI unit of illuminance, one lumen per square meter. The foot-candle (fc) — also written "foot candles" without the hyphen — is one lumen per square foot. Because the foot is defined as exactly 0.3048 m, one square foot is exactly 0.3048² = 0.09290304 m², so the ratio between the two units is exact: multiply lux by 0.09290304 to get foot-candles, or multiply foot-candles by 10.7639104167 to get lux.

Rough everyday levels: a well-lit office is typically designed for about 300 to 500 lx (roughly 28 to 46 fc), an overcast day gives on the order of 1,000 lx outdoors, and direct summer sunlight can reach around 100,000 lx. Do not confuse illuminance with luminance: illuminance (lux, foot-candles) is light falling on a surface, while luminance (candela per square meter, or nits) is how bright a surface or screen looks from a given direction.

Illuminance is light falling on a surface. Light coming off a screen or a sign is luminance: see nits to foot-lamberts. One lux is one lumen per square meter, so the area calculator helps when planning how far a lamp’s lumens spread.

Frequently asked questions

Is lux the same as foot candles?

No. Both measure illuminance, but lux is the SI unit (one lumen per square meter) and the foot-candle is the US customary unit (one lumen per square foot). One lux is about 0.0929 foot-candles, so the two scales differ by that factor.

Is lux the same as lumens?

No. Lumens measure the total visible light a source emits; lux measures how much of that light lands on each square meter of a surface. A 5,000 lumen fixture spread evenly over 10 m² gives 500 lx, not 5,000 lx — the two are equal only when the light spreads over exactly 1 m².

How many foot-candles are in one lux?

One lux is exactly 0.09290304 foot-candles. Both units are defined exactly, so the factor has no rounding.

How do I convert lux to foot-candles?

Multiply the number of lux by 0.09290304. For example, 300 lx × 0.09290304 = 27.870912 fc.

How do I convert foot-candles back to lux?

Divide by 0.09290304, or multiply by 10.7639104167. For example, 50 fc = 538.195520835 lx.

How many lumens are needed to light an area to a given lux level?

Multiply the target lux by the area in square meters, since one lux is one lumen per square meter. A 4 m² desk lit to 250 lx needs about 250 × 4 = 1,000 lumens reaching the surface, the same level as 23.23 fc (250 lx × 0.09290304).

Sources and further reading

  1. The International System of Units (SI Brochure), 9th edition (opens in a new tab), Bureau International des Poids et Mesures
  2. NIST Guide to the SI (Special Publication 811) (opens in a new tab), National Institute of Standards and Technology
  3. 29 CFR 1926.56 – Illumination (Table D-3) (opens in a new tab), Occupational Safety and Health Administration (OSHA)