Viscosity converter (dynamic): cP, Pa·s, poise
To convert viscosity, multiply by the starting unit's size in Pa·s and divide by the target unit's.
1 cP = 1 mPa·s = 0.001 Pa·s exactly, and 1 poise (P) = 100 cP = 0.1 Pa·s. So water at 20 °C, about 1.002 cP, is about 0.001002 Pa·s.
cP to cSt calculator (dynamic to kinematic viscosity)
Centipoise and centistokes measure different things, so converting between them needs the fluid's density: cSt = cP ÷ density in g/cm³, and cP = cSt × density in g/cm³. One cSt is exactly one mm²/s. Use the density at the same temperature as the viscosity.
Worked examples
Convert 500 cP to Pa·s
500 cP × 0.001 Pa·s/cP = 0.5 Pa·s
One centipoise is exactly 0.001 Pa·s, so divide by 1,000. The centipoise to pascal seconds converter has a full table.
Convert 2.5 poise to centipoise and Pa·s
2.5 P × 100 = 250 cP; 2.5 P × 0.1 = 0.25 Pa·s
A centipoise is one hundredth of a poise, just as a centimeter is one hundredth of a meter.
Convert glycerol at 1.412 Pa·s to cP and mPa·s
1.412 Pa·s × 1,000 = 1,412 cP = 1,412 mPa·s
Pure glycerol at 20 °C is about 1,410 times as viscous as water.
Convert water at 20 °C (1.0016 mPa·s) to lb/(ft·s)
1.0016 mPa·s = 0.0010016 Pa·s; 0.0010016 ÷ 1.488164 ≈ 0.000673 lb/(ft·s)
One pound per foot-second is 0.45359237 kg ÷ 0.3048 m ≈ 1.488164 Pa·s.
Convert an oil at 0.8 Pa·s to reyns
0.8 Pa·s ÷ 6,894.757 Pa·s/reyn ≈ 1.16 × 10⁻⁴ reyn (116 microreyn)
Bearing design charts often quote lubricant viscosity in microreyns because the reyn is so large.
Convert 90 cP to cSt for an oil with density 0.90 g/cm³
90 cP ÷ 0.90 g/cm³ = 100 cSt
This step needs the density, so it is a kinematic conversion. Use the kinematic viscosity converter to change cSt into other kinematic units.
Viscosity conversion chart: cP to Pa·s, poise and lbf·s/ft²
| Centipoise (cP) | Pascal seconds (Pa·s) | Poise (P) | Pound-force seconds per square foot (lbf·s/ft²) |
|---|---|---|---|
| 0.01 | 0.00001 | 0.0001 | 0.000000208854 |
| 0.1 | 0.0001 | 0.001 | 0.00000208854 |
| 0.5 | 0.0005 | 0.005 | 0.0000104427 |
| 1 | 0.001 | 0.01 | 0.0000208854 |
| 2 | 0.002 | 0.02 | 0.0000417709 |
| 5 | 0.005 | 0.05 | 0.000104427 |
| 10 | 0.01 | 0.1 | 0.000208854 |
| 20 | 0.02 | 0.2 | 0.000417709 |
| 50 | 0.05 | 0.5 | 0.00104427 |
| 100 | 0.1 | 1 | 0.00208854 |
| 200 | 0.2 | 2 | 0.00417709 |
| 500 | 0.5 | 5 | 0.0104427 |
| 1,000 | 1 | 10 | 0.0208854 |
| 2,000 | 2 | 20 | 0.0417709 |
| 5,000 | 5 | 50 | 0.104427 |
| 10,000 | 10 | 100 | 0.208854 |
| 50,000 | 50 | 500 | 1.04427 |
| 100,000 | 100 | 1,000 | 2.08854 |
Pa·s to cP conversion chart
| Pascal seconds (Pa·s) | Centipoise (cP) | Poise (P) | Reyns |
|---|---|---|---|
| 0.001 | 1 | 0.01 | 0.000000145038 |
| 0.01 | 10 | 0.1 | 0.00000145038 |
| 0.1 | 100 | 1 | 0.0000145038 |
| 0.5 | 500 | 5 | 0.0000725189 |
| 1 | 1,000 | 10 | 0.000145038 |
| 2 | 2,000 | 20 | 0.000290075 |
| 5 | 5,000 | 50 | 0.000725189 |
| 10 | 10,000 | 100 | 0.00145038 |
| 50 | 50,000 | 500 | 0.00725189 |
| 100 | 100,000 | 1,000 | 0.0145038 |
| 1,000 | 1,000,000 | 10,000 | 0.145038 |
Viscosity of common fluids
| Fluid | Millipascal seconds (mPa·s) | Pascal seconds (Pa·s) | Poise (P) | Pounds per foot-hour (lb/, ft·h) |
|---|---|---|---|---|
| Air, 20 °C | 0.0181 | 0.0000181 | 0.000181 | 0.043785 |
| Water, 50 °C | 0.5465 | 0.0005465 | 0.005465 | 1.322 |
| Water, 25 °C | 0.89 | 0.00089 | 0.0089 | 2.153 |
| Water, 20 °C | 1.0016 | 0.0010016 | 0.010016 | 2.423 |
| Ethanol, 20 °C | 1.2 | 0.0012 | 0.012 | 2.9029 |
| Mercury, 25 °C | 1.526 | 0.001526 | 0.01526 | 3.6915 |
| Olive oil, 20 °C (typical) | 84 | 0.084 | 0.84 | 203.2 |
| Castor oil, 20 °C | 986 | 0.986 | 9.86 | 2,385.2 |
| Glycerol, 20 °C | 1,412 | 1.412 | 14.12 | 3,415.8 |
About dynamic viscosity units
Dynamic (absolute) viscosity is a fluid's resistance to shear flow, the shear stress needed per unit velocity gradient; its SI unit is the pascal second.
Dynamic viscosity, also called absolute viscosity and written μ or η, is the shear stress in a fluid divided by its shear rate: μ = τ ÷ (du/dy). Push the top of a fluid layer 1 mm thick at 1 m/s and the shear rate is 1,000 s⁻¹. If that takes a stress of 1 Pa, the fluid's viscosity is 1 ÷ 1,000 = 0.001 Pa·s, which is 1 cP, about the viscosity of water. Its SI unit is the pascal second (Pa·s = N·s/m² = kg/(m·s)). The CGS unit, the poise, is one dyne-second per square centimeter, exactly 0.1 Pa·s.
Because 1 P = 0.1 Pa·s, the centipoise (0.01 P) is exactly 0.001 Pa·s, the same as one millipascal second. Data sheets switch freely between cP and mPa·s, and the numbers are identical. To convert any pair, the converter multiplies your value by the starting unit's size in pascal seconds and divides by the target unit's. Gas viscosities are small, so they are often given in micropoise or µPa·s: air at 20 °C is about 18.1 µPa·s, which is 181 µP or 0.0181 cP.
US engineering and lubrication references use pound-based units. One pound-force second per square foot (lbf·s/ft², equal to one slug per foot-second) is about 47.8803 Pa·s, or 47,880 cP. The reyn, one pound-force second per square inch, is about 6,894.76 Pa·s, the same number as one psi in pascals. Mass-based units such as the pound per foot-second (about 1.48816 Pa·s) and the pound per foot-hour (about 0.413 cP) appear in heat-transfer tables. All of these factors are exact, because the pound, the foot and standard gravity are defined exactly.
Do not mix dynamic viscosity up with kinematic viscosity, ν = μ ÷ ρ, which is measured in m²/s, stokes or centistokes (cSt), and 1 cSt is exactly 1 mm²/s. To turn cP into cSt (or mm²/s), divide by the density in g/cm³; to go from cSt back to cP, multiply by it. An oil at 90 cP with a density of 0.90 g/cm³ is 100 cSt, and the cP to cSt calculator above does this for you. Water at 20 °C is 1.0016 mPa·s ÷ 0.99821 g/cm³ ≈ 1.003 cSt. Use the kinematic viscosity converter for those units. Viscosity also falls fast as a liquid warms. Water drops from 1.0016 cP at 20 °C to 0.890 cP at 25 °C and 0.547 cP at 50 °C (IAPWS), so always quote a temperature with a viscosity.
Dynamic viscosity divided by density gives kinematic viscosity: see the kinematic viscosity converter and the density converter.
Every factor here is exact, because each unit is defined exactly in terms of the others. How unit conversion works explains the method.
One centipoise in every unit
| Unit | Symbol | Value |
|---|---|---|
| Pascal seconds | Pa·s | 0.001 |
| Millipascal seconds | mPa·s | 1 |
| Poise | P | 0.01 |
| Centipoise | cP | 1 |
| Micropoise | µP | 10,000 |
| Pounds per foot-second | lb/(ft·s) | 0.00067196897514 |
| Pounds per foot-hour | lb/(ft·h) | 2.4190883105 |
| Pound-force seconds per square foot | lbf·s/ft² | 0.0000208854342332 |
| Reyns | reyn | 0.00000014503773773 |
| Kilogram-force seconds per square meter | kgf·s/m² | 0.000101971621298 |
Unit definitions
| Unit | System | Definition |
|---|---|---|
| Pascal second (Pa·s) | SI | The pascal second is the SI unit of dynamic viscosity, equal to one newton-second per square meter (1 Pa·s = 1 N·s/m² = 1 kg/(m·s)). Honey at room temperature is typically a few pascal seconds. |
| Millipascal second (mPa·s) | SI | A millipascal second is one thousandth of a pascal second and is exactly equal to one centipoise. Water at 20 °C is about 1.0 mPa·s. |
| Poise (P) | Metric | The poise is the CGS unit of dynamic viscosity, one dyne-second per square centimeter, exactly 0.1 Pa·s. It is named after Jean Léonard Marie Poiseuille. |
| Centipoise (cP) | Metric | A centipoise is one hundredth of a poise, exactly 0.001 Pa·s (1 mPa·s). It is widely used in industry; water at 20 °C is about 1.002 cP. |
| Micropoise (µP) | Metric | A micropoise is 10⁻⁶ poise, or 10⁻⁷ Pa·s, a convenient size for gas viscosities (air at 20 °C is about 181 µP). |
| Pound per foot-second (lb/(ft·s)) | Imperial and US | One pound (mass) per foot-second is about 1.48816 Pa·s, the viscosity unit of the foot-pound-second system based on mass. |
| Pound per foot-hour (lb/(ft·h)) | Imperial and US | One pound per foot-hour is about 0.000413379 Pa·s (0.413 cP), used in some US heat-transfer tables. |
| Pound-force second per square foot (lbf·s/ft²) | Imperial and US | One pound-force second per square foot (equal to one slug per foot-second) is about 47.8803 Pa·s, the viscosity unit of US engineering fluid mechanics. |
| Reyn (reyn) | Imperial and US | The reyn is one pound-force second per square inch, about 6,894.76 Pa·s. It is named after Osborne Reynolds and is used in lubrication engineering. |
| Kilogram-force second per square meter (kgf·s/m²) | Metric | One kilogram-force second per square meter is exactly 9.80665 Pa·s, from the older gravitational metric system. |
Popular dynamic viscosity conversions
Frequently asked questions
How do I convert viscosity units?
Multiply by the starting unit's size in Pa·s, then divide by the target unit's size. The key exact factors are 1 cP = 1 mPa·s = 0.001 Pa·s, 1 P = 100 cP = 0.1 Pa·s and 1 lbf·s/ft² ≈ 47.8803 Pa·s. So 250 cP is 0.25 Pa·s or 2.5 P.
How do I convert centipoise to Pa·s?
Divide by 1,000. For example, 500 cP is 0.5 Pa·s, and a motor oil at 250 cP is 0.25 Pa·s. To go from Pa·s to cP, multiply by 1,000.
Is a centipoise the same as a millipascal second?
Yes. One centipoise is exactly 0.001 Pa·s, which is one millipascal second, so values in cP and mPa·s are numerically identical.
How do I convert cP to cSt or mm²/s?
Divide the dynamic viscosity in cP by the density in g/cm³: cSt = cP ÷ ρ. An oil at 90 cP with a density of 0.90 g/cm³ is 100 cSt, which is also 100 mm²/s. To go from cSt to cP, multiply by the density instead. Without the density you cannot convert between them, because cP measures dynamic viscosity and cSt measures kinematic viscosity.
What is the formula for dynamic viscosity?
Dynamic viscosity is shear stress divided by shear rate, μ = τ ÷ (du/dy). A stress of 2 Pa that shears a fluid at 400 s⁻¹ gives μ = 2 ÷ 400 = 0.005 Pa·s, which is 5 cP. Viscometers measure it this way, from the torque or flow time at a known shear rate.
What is the viscosity of water?
About 1.0016 mPa·s (1.002 cP) at 20 °C and 0.890 mPa·s at 25 °C. By 50 °C it has fallen to about 0.547 mPa·s. These values are from the IAPWS 2008 formulation.
Sources and further reading
- NIST Guide to the SI (Special Publication 811), Appendix B: Conversion Factors (opens in a new tab), National Institute of Standards and Technology
- New International Formulation for the Viscosity of H₂O (Huber and others, Journal of Physical and Chemical Reference Data 38, 101–125, 2009) (opens in a new tab), AIP Publishing for the International Association for the Properties of Water and Steam
- CRC Handbook of Chemistry and Physics, CRC Press