Unit converter

Equivalent dose converter (Sv, mSv, rem, mrem)

To convert sievert to rem, multiply by 100: 1 Sv = 100 rem exactly.

Sv

1 sievert equals

100rem

rem = Sv × 100

Exact conversion factor1 Sv = 100 rem1 rem = 0.01 Sv

To convert rem to sievert, divide by 100, so 1 rem = 0.01 Sv (10 mSv). The same factor links the smaller units: 1 mSv = 100 mrem, so a 2.4 mSv yearly background dose is 240 mrem.

7 unitsBy Hira Noor, mathematicianLast reviewed Report a problem

Worked examples

  1. Convert 0.05 Sv to rem

    0.05 Sv × 100 = 5 rem

    This is the US annual occupational limit, 50 mSv or 5 rem.

  2. Convert 25 rem to sieverts

    25 rem ÷ 100 = 0.25 Sv

    Dividing by 100 moves the decimal point two places to the left; 0.25 Sv is 250 mSv.

  3. Convert 2.4 mSv to mrem

    2.4 mSv × 100 = 240 mrem

    Millisieverts to millirem uses the same factor of 100 as sieverts to rem.

  4. Convert 10 mSv to rem

    10 mSv ÷ 1,000 = 0.01 Sv, then 0.01 Sv × 100 = 1 rem

    Shortcut: divide millisieverts by 10 to get rem.

  5. Convert 0.3 µSv/h to mrem/h

    0.3 µSv/h ÷ 10 = 0.03 mrem/h

    One microsievert is 0.1 mrem, so divide microsieverts by 10. The time basis (per hour) is unchanged.

Sievert to rem conversion chart

Sieverts (Sv) to rem, millisieverts (mSv), millirem (mrem)
Sieverts (Sv)RemMillisieverts (mSv)Millirem (mrem)
0.00010.010.110
0.0010.11100
0.00240.242.4240
0.0050.55500
0.011101,000
0.022202,000
0.055505,000
0.11010010,000
0.252525025,000
0.55050050,000
11001,000100,000
22002,000200,000
44004,000400,000
55005,000500,000
101,00010,0001,000,000
10010,000100,00010,000,000

Millisievert to millirem conversion chart

Millisieverts (mSv) to millirem (mrem), rem
Millisieverts (mSv)Millirem (mrem)Rem
0.0110.001
0.1100.01
0.5500.05
11000.1
22000.2
2.42400.24
33000.3
55000.5
6.26200.62
101,0001
202,0002
505,0005
10010,00010
25025,00025
50050,00050
1,000100,000100

Rem to sievert conversion chart

Rem to sieverts (Sv), millisieverts (mSv)
RemSieverts (Sv)Millisieverts (mSv)
0.10.0011
0.50.0055
10.0110
20.0220
50.0550
100.1100
250.25250
500.5500
750.75750
10011,000
20022,000
40044,000
50055,000
1,0001010,000

About equivalent dose units

Equivalent dose is absorbed radiation dose weighted for the biological effectiveness of the radiation type; its SI unit is the sievert, the same unit used for effective dose.

The sievert (Sv) is the SI unit of equivalent dose and effective dose. The rem (roentgen equivalent man) is the older unit still used in US regulations and dose reports. The rem is defined as exactly 0.01 Sv, so every conversion here is a power of ten: 1 Sv = 100 rem, 1 mSv = 100 mrem and 1 µSv = 0.1 mrem. Nothing is rounded. For one direction with its own table and worked examples, use the rem to sieverts converter or the sieverts to rem converter.

The factor of 100 comes from the absorbed-dose units underneath. Equivalent dose is absorbed dose multiplied by a radiation weighting factor, which ICRP Publication 103 sets at 1 for X-rays, gamma rays and electrons, 20 for alpha particles, and an energy-dependent value for neutrons. Sieverts are built on grays, rem on rads, and 1 Gy = 100 rad, so 1 Sv = 100 rem. Effective dose then weights each organ by its sensitivity but keeps the same unit. For the unweighted physical dose, use the gray to rad converter.

In practice you convert in both directions. US Nuclear Regulatory Commission rules limit a radiation worker to 5 rem (50 mSv) a year and a member of the public to 0.1 rem (1 mSv, or 100 mrem) from a licensed source. UNSCEAR puts the worldwide average natural background at about 2.4 mSv (240 mrem) a year, and the NRC gives about 620 mrem (6.2 mSv) as the average total for people in the United States, including medical scans. A chest X-ray is about 0.1 mSv (10 mrem) and an abdominal CT scan about 10 mSv (1 rem). More values are in the typical doses table.

Two older units cause confusion. The rad measures absorbed energy, not weighted dose: for X-rays and gamma rays 1 rad gives 1 rem, but for alpha particles 1 rad gives 20 rem. The roentgen (R) measures exposure, the charge gamma or X-rays produce in air; 1 R delivers roughly 0.0096 Sv to soft tissue, close to 1 rem. Survey meters often read a dose rate, such as µSv/h or mrem/h, so multiply by the time before comparing with a dose.

Equivalent dose comes from the absorbed dose in grays: see grays to rads. Doses in millisieverts and microsieverts are powers of ten, which the scientific notation calculator handles.

Every factor here is exact, because each unit is defined exactly in terms of the others. How unit conversion works explains the method.

One sievert in every unit

1 sievert in every equivalent dose unit
UnitSymbolValue
SievertsSv1
MillisievertsmSv1,000
MicrosievertsµSv1,000,000
NanosievertsnSv1,000,000,000
Remrem100
Milliremmrem100,000
Microremµrem100,000,000

Unit definitions

Definitions of equivalent dose units
UnitSystemDefinition
Sievert (Sv)SIThe sievert is the SI unit of equivalent and effective dose. It equals one joule per kilogram after weighting for radiation type (and, for effective dose, for tissue sensitivity).
Millisievert (mSv)SIA millisievert is one thousandth of a sievert. Annual background exposure and occupational dose limits are stated in mSv.
Microsievert (µSv)SIA microsievert is one millionth of a sievert. Survey meters and personal dosimeters often display dose rates in µSv per hour.
Nanosievert (nSv)SIA nanosievert is 10⁻⁹ sievert, used for environmental dose rates such as nSv per hour.
Rem (rem)HistoricalThe rem (roentgen equivalent man) is the older US unit of equivalent dose, exactly 0.01 sievert. US regulations still state limits in rem and millirem.
Millirem (mrem)HistoricalA millirem is one thousandth of a rem, exactly 10 µSv. US dose reports and radiation fact sheets commonly use mrem.
Microrem (µrem)HistoricalA microrem is one millionth of a rem, exactly 10 nSv, used on some survey meters for dose rates.

Frequently asked questions

What is 1 rem in sieverts?

One rem is exactly 0.01 Sv, which is 10 mSv. To convert rem to sieverts, divide by 100, so 5 rem = 0.05 Sv.

How many sieverts are in a rem?

There are 0.01 sieverts in a rem, or put the other way, 100 rem in one sievert. The factor is fixed by definition, so it is exact.

What is 1 sievert equal to?

One sievert equals 100 rem, 1,000 mSv, 100,000 mrem and 1,000,000 µSv. In base units it is one joule per kilogram, weighted for radiation type.

How do I convert mSv to rem?

Divide millisieverts by 10. One millisievert is 0.001 Sv, which is 0.1 rem, so 50 mSv = 5 rem. To get millirem instead, multiply mSv by 100.

How many sieverts is lethal?

The CDC gives the whole-body dose that kills about half of exposed people within 60 days as roughly 2.5 to 5 Gy, about 2.5 to 5 Sv (250 to 500 rem) for gamma rays. That is over 1,000 times a year of natural background. This is reference information, not medical advice.

Is a sievert the same as a gray?

They share the unit J/kg but measure different things. The gray is absorbed energy; the sievert weights it for radiation type. For X-rays and gamma rays 1 Gy gives 1 Sv, but for alpha particles 1 Gy gives 20 Sv.