Radioactivity converter
Convert radioactivity between becquerels and curies. One curie is exactly 3.7 × 10¹⁰ becquerels (37 GBq); divide becquerels by that same factor to get curies.
One millicurie is exactly 37 megabecquerels, so a 10 mCi dose is 370 MBq.
Curie to becquerel worked examples
Convert 1 Ci to Bq
1 Ci × 3.7 × 10¹⁰ = 3.7 × 10¹⁰ Bq (37 GBq)
This is close to the activity of one gram of radium-226, the sample the curie was originally based on.
Convert 15 Ci to Bq
15 Ci × 3.7 × 10¹⁰ = 5.55 × 10¹¹ Bq
Usually written as 555 GBq, or 0.555 TBq, for a source this active.
Convert 5 mCi to MBq
5 mCi × 37 = 185 MBq
A nuclear-medicine dose prescribed as 5 mCi in the US is charted as 185 MBq elsewhere.
Convert 10 MBq to mCi
10 MBq ÷ 37 = 0.270 mCi
Dividing megabecquerels by 37 gives millicuries directly, the reverse of the mCi-to-MBq shortcut above.
About radioactivity units
Radioactivity (activity) is the number of nuclear decays a radioactive sample undergoes per unit time; its SI unit is the becquerel, one decay per second.
The becquerel (Bq) is the SI unit of activity, one nuclear decay per second. It replaced the curie (Ci), which was originally based on the activity of one gram of radium-226 and is now defined as exactly 3.7 × 10¹⁰ Bq. Because that definition is exact, every curie to becquerel conversion here is exact as well.
The two units sit at opposite ends of the scale. A becquerel is tiny, so practical values use MBq, GBq or TBq; a curie is large, so US practice uses millicuries, microcuries and picocuries. Radon is a good example: the US EPA action level of 4 pCi/L equals 4 × 0.037 = 0.148 Bq per liter, or 148 Bq/m³.
Activity is not the same as dose. Activity counts decays in the source; absorbed dose (gray, rad) measures energy deposited in tissue, and equivalent dose (sievert, rem) weights it for biological effect. A highly active source can give a low dose if it is far away or well shielded. For dose units, see the absorbed dose converter and the equivalent dose converter.
One curie is 3.7 × 10¹⁰ becquerels, so results run to many digits; the scientific notation calculator works with them. The dose a source delivers is measured in grays, on the absorbed dose converter.
Every factor here is exact, because each unit is defined exactly in terms of the others. How unit conversion works explains the method.
One curie in every unit
| Unit | Symbol | Value |
|---|---|---|
| Terabecquerels | TBq | 0.037 |
| Gigabecquerels | GBq | 37 |
| Megabecquerels | MBq | 37,000 |
| Kilobecquerels | kBq | 37,000,000 |
| Becquerels | Bq | 37,000,000,000 |
| Curies | Ci | 1 |
| Millicuries | mCi | 1,000 |
| Microcuries | µCi | 1,000,000 |
| Nanocuries | nCi | 1,000,000,000 |
| Picocuries | pCi | 1,000,000,000,000 |
| Rutherfords | Rd | 37,000 |
| Disintegrations per minute | dpm | 2,220,000,000,000 |
Unit definitions
| Unit | System | Definition |
|---|---|---|
| Terabecquerel (TBq) | SI | A terabecquerel is 10¹² becquerels, used for industrial radiography and teletherapy sources. |
| Gigabecquerel (GBq) | SI | A gigabecquerel is 10⁹ becquerels, a common scale for radionuclide generators and therapy doses. |
| Megabecquerel (MBq) | SI | A megabecquerel is one million becquerels. Diagnostic nuclear-medicine doses are usually prescribed in MBq. |
| Kilobecquerel (kBq) | SI | A kilobecquerel is 1,000 becquerels, typical of laboratory check sources. |
| Becquerel (Bq) | SI | The becquerel is the SI unit of activity: one radioactive decay per second on average (1 Bq = 1 s⁻¹). It is a very small unit, so practical values carry prefixes. |
| Curie (Ci) | Historical | The curie is defined as exactly 3.7 × 10¹⁰ becquerels, close to the activity of one gram of radium-226. It is still common in the United States. |
| Millicurie (mCi) | Historical | A millicurie is one thousandth of a curie, exactly 37 MBq. US nuclear-medicine doses are often stated in mCi. |
| Microcurie (µCi) | Historical | A microcurie is one millionth of a curie, exactly 37 kBq, a typical activity for sealed calibration sources. |
| Nanocurie (nCi) | Historical | A nanocurie is 10⁻⁹ curie, exactly 37 becquerels. |
| Picocurie (pCi) | Historical | A picocurie is 10⁻¹² curie, exactly 0.037 becquerel. US radon levels are reported in picocuries per liter of air. |
| Rutherford (Rd) | Historical | The rutherford is an obsolete unit equal to one million decays per second, exactly 1 MBq. |
| Disintegration per minute (dpm) | Other | One disintegration per minute is one decay every 60 seconds, 1/60 becquerel. It is used in wipe tests and liquid scintillation counting. |
Popular radioactivity conversions
Frequently asked questions
How many becquerels are in a curie?
Exactly 3.7 × 10¹⁰ Bq, which is 37 GBq. The value is a definition, so the conversion has no rounding error.
How do I convert becquerels to curies?
Divide by 3.7 × 10¹⁰. One megabecquerel is 1 × 10⁶ ÷ 3.7 × 10¹⁰ ≈ 2.7027 × 10⁻⁵ Ci, or about 27.03 µCi.
How many MBq are in a millicurie?
Exactly 37 MBq. A 5 mCi injection is 185 MBq, and 370 MBq is 10 mCi.
What is 4 pCi/L of radon in Bq/m³?
Exactly 148 Bq/m³. One picocurie is 0.037 Bq and one cubic meter is 1,000 liters, so 4 × 0.037 × 1,000 = 148.
Sources and further reading
- The International System of Units (SI Brochure), 9th edition (opens in a new tab), Bureau International des Poids et Mesures
- NIST Guide to the SI (Special Publication 811) (opens in a new tab), National Institute of Standards and Technology
- Radiation Units and Conversion Factors (opens in a new tab), Radiation Emergency Medical Management (REMM), U.S. Department of Health and Human Services