Voltage converter (V, mV, kV)
To convert voltage units, multiply by the starting unit's size in volts and divide by the target unit's: 1 V = 1,000 mV and 1 kV = 1,000 V exactly, so 250 mV is 0.25 V. Changing a 120 V supply to 230 V is different: it needs a step-up or step-down converter.
Use the converter size calculator.
110 V and 220 V voltage converters: size calculator
A device that changes 220–240 V mains to 110–120 V is a step-down converter; one that changes 110–120 V to 220–240 V is a step-up converter. First check the appliance label: if it reads 100–240 V, it is dual voltage and needs only a plug adapter. If not, enter its power to find the smallest converter to buy. Converters do not change 50 Hz to 60 Hz.
The margins are common rules of thumb, not a standard: 1× for heating loads, 1.5× for electronics run for hours, and 3× (the top of the usual 2 to 3× range) for motors, which draw a surge when they start. Heating-only converters are for short use; electronics need a transformer. Current uses I = P ÷ V at 120 V and 230 V nominal.
Voltage conversion worked examples
Convert 250 mV to volts
250 mV ÷ 1,000 = 0.25 V
Divide millivolts by 1,000 for volts. A 4.1 mV thermocouple reading is 0.0041 V.
Convert 3.3 V to millivolts
3.3 V × 1,000 = 3,300 mV
Multiply volts by 1,000 for millivolts. A 1.5 V AA cell is 1,500 mV.
Convert 13.8 kV to volts and megavolts
13.8 kV × 1,000 = 13,800 V; 13,800 V ÷ 1,000,000 = 0.0138 MV
Distribution lines are rated in kilovolts; 13.8 kV is a common distribution voltage in North America.
Convert 50 µV to millivolts and volts
50 µV ÷ 1,000 = 0.05 mV; 50 µV ÷ 1,000,000 = 0.00005 V
EEG brain signals are tens of microvolts, so they are usually quoted in µV.
Size a step-down converter for a 150 W US television in the UK
150 W × 1.5 = 225 W, so choose a 230 V to 120 V transformer rated 300 W or more
The 50% margin covers long running hours. A 230 V supply would damage a 120 V-only set plugged in through an adapter.
Current drawn by a 1,500 W kettle at 120 V and 230 V
I = P ÷ V: 1,500 W ÷ 120 V = 12.5 A; 1,500 W ÷ 230 V = 6.52 A
The same power needs about twice the current at 120 V. That is why North American kettles stop near 1,500 W on 15 A circuits, while UK kettles reach 3 kW on a 13 A plug.
RMS to peak and peak-to-peak for 230 V mains
230 V × √2 = 325.3 V peak; 325.3 V × 2 = 650.5 V peak to peak
For 120 V mains: 169.7 V peak and 339.4 V peak to peak. Meters and outlet ratings show RMS.
Find voltage with Ohm's law: 20 mA through 150 Ω
V = I × R = 0.020 A × 150 Ω = 3 V = 3,000 mV
Convert milliamperes to amperes first, or the answer comes out 1,000 times too large.
Watts to volts: a 60 W load drawing 5 A
V = P ÷ I = 60 W ÷ 5 A = 12 V
Watts alone never give volts; you also need the current (or the resistance, with V = √(P × R)).
Convert 0 dBm into a 50 Ω load to volts
0 dBm = 1 mW; V = √(P × R) = √(0.001 W × 50 Ω) = 0.2236 V RMS = 223.6 mV
A dBm figure is a power level, so the voltage depends on the load impedance. By definition, 0 dBV is 1 V and 0 dBu is about 0.7746 V.
Voltage conversion chart: V to mV and kV
| Volts (V) | Millivolts (mV) | Kilovolts (kV) | Common use |
|---|---|---|---|
| 0.001 | 1 | 0.000001 | Thermocouple signals (about 0.04 mV per °C) |
| 0.01 | 10 | 0.00001 | |
| 0.1 | 100 | 0.0001 | |
| 0.5 | 500 | 0.0005 | |
| 1 | 1,000 | 0.001 | |
| 1.5 | 1,500 | 0.0015 | AA or AAA cell |
| 3.3 | 3,300 | 0.0033 | Logic supply for microcontrollers |
| 5 | 5,000 | 0.005 | USB power |
| 9 | 9,000 | 0.009 | PP3 battery |
| 12 | 12,000 | 0.012 | Car battery, LED strips |
| 24 | 24,000 | 0.024 | Truck and control circuits |
| 48 | 48,000 | 0.048 | Telecom DC, Power over Ethernet |
| 100 | 100,000 | 0.1 | Mains in Japan (50/60 Hz) |
| 120 | 120,000 | 0.12 | Mains in US, Canada, Mexico (60 Hz) |
| 127 | 127,000 | 0.127 | Mains in parts of Brazil (60 Hz) |
| 220 | 220,000 | 0.22 | Mains in China (50 Hz), South Korea (60 Hz) |
| 230 | 230,000 | 0.23 | Mains in UK, EU, India, Australia (50 Hz) |
| 240 | 240,000 | 0.24 | US split-phase circuits (dryers, ranges) |
| 400 | 400,000 | 0.4 | Three-phase supply in Europe (230/400 V) |
| 1,000 | 1,000,000 | 1 |
mV to V chart
| Millivolts (mV) | Volts (V) | Microvolts (µV) |
|---|---|---|
| 0.001 | 0.000001 | 1 |
| 0.01 | 0.00001 | 10 |
| 0.1 | 0.0001 | 100 |
| 1 | 0.001 | 1,000 |
| 5 | 0.005 | 5,000 |
| 10 | 0.01 | 10,000 |
| 20 | 0.02 | 20,000 |
| 50 | 0.05 | 50,000 |
| 100 | 0.1 | 100,000 |
| 250 | 0.25 | 250,000 |
| 500 | 0.5 | 500,000 |
| 750 | 0.75 | 750,000 |
| 1,000 | 1 | 1,000,000 |
| 1,500 | 1.5 | 1,500,000 |
| 3,300 | 3.3 | 3,300,000 |
| 5,000 | 5 | 5,000,000 |
kV to V chart
| Kilovolts (kV) | Volts (V) | Megavolts (MV) |
|---|---|---|
| 0.4 | 400 | 0.0004 |
| 1 | 1,000 | 0.001 |
| 4.16 | 4,160 | 0.00416 |
| 11 | 11,000 | 0.011 |
| 13.8 | 13,800 | 0.0138 |
| 25 | 25,000 | 0.025 |
| 33 | 33,000 | 0.033 |
| 66 | 66,000 | 0.066 |
| 110 | 110,000 | 0.11 |
| 132 | 132,000 | 0.132 |
| 230 | 230,000 | 0.23 |
| 345 | 345,000 | 0.345 |
| 400 | 400,000 | 0.4 |
| 500 | 500,000 | 0.5 |
| 765 | 765,000 | 0.765 |
About voltage units
Voltage (electric potential difference) is the work done per unit charge in moving a charge between two points; its SI unit is the volt, one joule per coulomb.
The volt (V) is the SI unit of electric potential difference, equal to one joule per coulomb or one watt per ampere. Every SI-prefixed unit here is an exact power of ten: 1 MV = 10⁶ V, 1 kV = 10³ V, 1 mV = 10⁻³ V, 1 µV = 10⁻⁶ V and 1 nV = 10⁻⁹ V, so each prefix step is a factor of 1,000. The CGS units are exact too: one statvolt is 299.792458 V and one abvolt is 10⁻⁸ V. To convert any pair, go through volts: 4.1 mV × 0.001 = 0.0041 V, and 13,800 V ÷ 1,000 = 13.8 kV. The two most searched pairs have their own pages: mV to V and V to mV.
"Voltage converter" also names a device that changes the voltage of a mains supply so an appliance from one country works in another. Homes in the United States, Canada and Mexico get about 120 V at 60 Hz; the UK, Europe, India and Australia get 230 V at 50 Hz; Japan uses 100 V, at 50 Hz in the east and 60 Hz in the west. Labels of 110 V, 115 V and 120 V describe the same North American supply, and 220 V, 230 V and 240 V the same kind of supply elsewhere, so a device rated for one works on the others. A step-down converter takes 220–240 V to 110–120 V for an American appliance abroad, and a step-up converter does the reverse. First read the rating label: a charger marked "INPUT 100–240V ~ 50/60Hz" is dual voltage and needs only a plug adapter, which changes the plug shape but not the voltage.
Size a converter by power, using P = V × I. Its rating in watts should be at least the appliance's wattage; a common rule is to add 50% for electronics run for hours and to allow two to three times the rating for motors, compressors and pumps, which draw a surge when they start. Lightweight "heating-only" converters suit hair dryers and irons for short use; electronics need a transformer. A voltage converter does not change frequency, so a 60 Hz motor or mains-timed clock on 50 Hz power runs about 17% slow; see the frequency converter for 50 Hz and 60 Hz. This page converts units of voltage; it cannot change the voltage of an outlet.
Voltage, current and resistance are linked by Ohm's law, V = I × R: a 20 mA current through a 150 Ω resistor drops 0.020 × 150 = 3 V. Volts cannot be converted into watts or amps on their own; you need the third quantity, as in V = P ÷ I. Put each value into base units first with the electric current converter, the resistance converter and the power converter. Mains ratings are RMS values: a 120 V outlet peaks at 120 × √2 ≈ 170 V and a 230 V outlet at about 325 V, with twice that from peak to peak. Keep RMS with RMS and peak with peak, because this converter changes units only.
Ohm’s law links volts to amps and ohms (V = I × R): see the current converter and the resistance converter. Power is volts times amps, on the power converter.
Every factor here is exact, because each unit is defined exactly in terms of the others. How unit conversion works explains the method.
One volt in every unit
| Unit | Symbol | Value |
|---|---|---|
| Megavolts | MV | 0.000001 |
| Kilovolts | kV | 0.001 |
| Volts | V | 1 |
| Millivolts | mV | 1,000 |
| Microvolts | µV | 1,000,000 |
| Nanovolts | nV | 1,000,000,000 |
| Abvolts | abV | 100,000,000 |
| Statvolts | statV | 0.00333564095198 |
Unit definitions
| Unit | System | Definition |
|---|---|---|
| Megavolt (MV) | SI | A megavolt is one million volts, the scale of lightning, particle accelerators and radiotherapy beam energies. |
| Kilovolt (kV) | SI | A kilovolt is 1,000 volts. Power distribution and transmission lines are rated in kilovolts. |
| Volt (V) | SI | The volt is the SI unit of electric potential difference: one joule of energy per coulomb of charge (1 V = 1 J/C = 1 W/A). |
| Millivolt (mV) | SI | A millivolt is one thousandth of a volt, the range of thermocouple outputs, sensor signals and nerve membrane potentials. |
| Microvolt (µV) | SI | A microvolt is one millionth of a volt, typical of EEG brain signals and radio receiver sensitivity. |
| Nanovolt (nV) | SI | A nanovolt is 10⁻⁹ volts, used for amplifier noise figures and precision metrology. |
| Abvolt (abV) | Historical | The abvolt is the electromagnetic CGS unit of potential difference, exactly 10⁻⁸ volt. |
| Statvolt (statV) | Historical | The statvolt is the Gaussian CGS unit of potential difference, exactly 299.792458 volts (c/10⁶ with c in m/s). |
Popular voltage conversions
Frequently asked questions
What is a voltage converter?
It has two meanings. As a tool like this one, it converts a voltage between units such as volts, millivolts and kilovolts: 1 V = 1,000 mV and 1 kV = 1,000 V. As a device, it changes a mains supply from one voltage to another, such as 230 V to 120 V, so an appliance can be used in another country.
What is 1 volt equal to, and how do I convert mV to V?
One volt is exactly 1,000 millivolts, 1,000,000 microvolts and 0.001 kilovolts; in SI terms it is one joule per coulomb, or one watt per ampere. Divide millivolts by 1,000 to get volts and multiply volts by 1,000 to get millivolts, so 500 mV = 0.5 V and 3.3 V = 3,300 mV.
How do I reduce voltage from 220 V to 110 V?
Use a step-down converter or transformer with an input of 220–240 V and an output of 110–120 V, rated in watts above the appliance's wattage (about 50% more for electronics). Check the label first: devices marked 100–240 V need only a plug adapter.
How can I convert 120 volts to 220 volts?
Use a step-up converter or transformer with a 110–120 V input and a 220–240 V output, sized above the appliance's wattage. A plug adapter alone changes only the plug shape, not the voltage, and a 230 V appliance on 120 V will underperform or fail to start.
What size voltage converter do I need?
Find the wattage on the appliance label (or multiply volts by amps: W = V × A) and choose a converter rated at least that high. Add about 50% for electronics used for long periods, and allow two to three times the rating for motors, compressors and pumps because of their starting surge.
Does a voltage converter change 50 Hz to 60 Hz?
No. Voltage converters and transformers keep the frequency of the supply. Most chargers and electronics are rated 50/60 Hz and do not mind, but motors and mains-timed clocks run slower on 50 Hz than on 60 Hz.
Sources and further reading
- The International System of Units (SI Brochure), 9th edition (opens in a new tab), Bureau International des Poids et Mesures
- NIST Guide to the SI (Special Publication 811) (opens in a new tab), National Institute of Standards and Technology
- World Plugs: electricity by country (voltage, frequency and plug type) (opens in a new tab), International Electrotechnical Commission